diff options
Diffstat (limited to 'docs')
-rw-r--r-- | docs/feature_haptic_feedback.md | 32 |
1 files changed, 19 insertions, 13 deletions
diff --git a/docs/feature_haptic_feedback.md b/docs/feature_haptic_feedback.md index 63ac4305ff..f4546b6914 100644 --- a/docs/feature_haptic_feedback.md +++ b/docs/feature_haptic_feedback.md @@ -50,22 +50,28 @@ Not all keycodes below will work depending on which haptic mechanism you have ch ### Solenoids -First you will need a build a circuit to drive the solenoid through a mosfet as most MCU will not be able to provide the current needed to drive the coil in the solenoid. +The solenoid code supports relay switches, and similar hardware, as well as solenoids. -[Wiring diagram provided by Adafruit](https://cdn-shop.adafruit.com/product-files/412/solenoid_driver.pdf) +For a regular solenoid, you will need a build a circuit to drive the solenoid through a mosfet as most MCU will not be able to provide the current needed to drive the coil in the solenoid. +[Wiring diagram provided by Adafruit](https://cdn-shop.adafruit.com/product-files/412/solenoid_driver.pdf) -| Settings | Default | Description | -|----------------------------|----------------------|-------------------------------------------------------| -|`SOLENOID_PIN` | *Not defined* |Configures the pin that the Solenoid is connected to. | -|`SOLENOID_PIN_ACTIVE_LOW` | *Not defined* |If defined then the solenoid trigger pin is active low.| -|`SOLENOID_DEFAULT_DWELL` | `12` ms |Configures the default dwell time for the solenoid. | -|`SOLENOID_MIN_DWELL` | `4` ms |Sets the lower limit for the dwell. | -|`SOLENOID_MAX_DWELL` | `100` ms |Sets the upper limit for the dwell. | -|`SOLENOID_DWELL_STEP_SIZE` | `1` ms |The step size to use when `HPT_DWL*` keycodes are sent | -|`SOLENOID_DEFAULT_BUZZ` | `0` (disabled) |On HPT_RST buzz is set "on" if this is "1" | -|`SOLENOID_BUZZ_ACTUATED` | `SOLENOID_MIN_DWELL` |Actuated-time when the solenoid is in buzz mode | -|`SOLENOID_BUZZ_NONACTUATED` | `SOLENOID_MIN_DWELL` |Non-Actuated-time when the solenoid is in buzz mode | +For relay switches, the hardware may already contain all of that ciruitry, and just require VCC, GND and a data pin. + +| Settings | Default | Description | +|----------------------------|----------------------|--------------------------------------------------------------| +|`SOLENOID_PIN` | *Not defined* |Configures the pin that the switch is connected to. | +|`SOLENOID_PIN_ACTIVE_LOW` | *Not defined* |If defined then the switch trigger pin is active low. | +|`SOLENOID_PINS` | *Not defined* |Configures an array of pins to be used for switch activation. | +|`SOLENOID_PINS_ACTIVE_LOW` | *Not defined* |Allows you to specify how each pin is pulled for activation. | +|`SOLENOID_RANDOM_FIRE` | *Not defined* |When there are multiple solenoids, will select a random one to fire.| +|`SOLENOID_DEFAULT_DWELL` | `12` ms |Configures the default dwell time for the switch. | +|`SOLENOID_MIN_DWELL` | `4` ms |Sets the lower limit for the dwell. | +|`SOLENOID_MAX_DWELL` | `100` ms |Sets the upper limit for the dwell. | +|`SOLENOID_DWELL_STEP_SIZE` | `1` ms |The step size to use when `HPT_DWL*` keycodes are sent. | +|`SOLENOID_DEFAULT_BUZZ` | `0` (disabled) |On HPT_RST buzz is set "on" if this is "1" | +|`SOLENOID_BUZZ_ACTUATED` | `SOLENOID_MIN_DWELL` |Actuated-time when the switch is in buzz mode. | +|`SOLENOID_BUZZ_NONACTUATED` | `SOLENOID_MIN_DWELL` |Non-Actuated-time when the switch is in buzz mode. | * If solenoid buzz is off, then dwell time is how long the "plunger" stays activated. The dwell time changes how the solenoid sounds. * If solenoid buzz is on, then dwell time sets the length of the buzz, while `SOLENOID_BUZZ_ACTUATED` and `SOLENOID_BUZZ_NONACTUATED` set the (non-)actuation times withing the buzz period. |