| Commit message (Collapse) | Author | Age | Files | Lines |
|
|
|
|
|
|
| |
Add OSMO_STAT_ITEM_NO_UNIT for stat items without an unit. The
statsd reporter uses gauges ("g") to report them.
Sponsored-by: On-Waves ehf
|
|
|
|
|
|
|
| |
Shipping our own private copy of talloc was a good idea in 2008,
when it was not readily available on most target platforms. Today,
the situation is quite different, as it is a standard library on
major Linux distributions.
|
|
|
|
|
| |
This was pointed out by Jaroslav Skarvada during fedora packaging,
and he has a valid point...
|
|
|
|
| |
Signed-off-by: Jaroslav Škarvada <jskarvad@redhat.com>
|
|
|
|
|
|
|
| |
Potentially Fixes:
<command id='show stats level (global|peer|subscriber)'>
<param name='subscriber' doc='(null)' />
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Currently there is only the 'show stats' command which shows all
counter and stat_item values. This can lead to many lines of output
if there are per-subscriber rate counters.
The new command added by this commit allows it to only show groups of
a certain level (class_id), similar to the 'level' configuration
command for stats reporter.
The new command is
show stats level (global|peer|subscriber)
Sponsored-by: On-Waves ehf
|
|
|
|
|
| |
Bump the ABI version of libosmovty and we need to do this
recursively to force rebuilds of our software.
|
|
|
|
|
|
|
| |
For the atoi we need to pass the val as a string. This means
we need to write "0" which then gets parsed to 0.
[src/vty/stats_vty.c:90]: (error) Possible null pointer dereference: val
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
This commit adds class_id fields to the rate_ctr and stat_item group
descriptions. The stats reporter code is extended to only process
groups whose class_id does not exceed a per reporter max_class level.
If the class_id is not set, the code assumes 'global' for groups with
idx == 0 and 'subscriber' otherwise.
The following vty command is added to config-stats:
level (global|peer|subscriber) Set the maximum group level
Sponsored-by: On-Waves ehf
|
|
|
|
|
|
|
|
|
|
| |
Since the the stat_item and stats functions and data types are meant
to be exported, they get an osmo_ prefix.
Sponsored-by: On-Waves ehf
[hfreyther: Prepended the enum values too. This was requested by
Jacob]
|
|
|
|
|
|
|
| |
This reporter passes the measurement values to the logging subsystem
as DSTATS (which is currently DLGLOBAL) level INFO messages.
Sponsored-by: On-Waves ehf
|
|
|
|
|
|
|
|
| |
To support reporters without network configuration, this commit
introduces the have_net_config flag to provide corresponding error
messages.
Sponsored-by: On-Waves ehf
|
|
|
|
|
|
|
| |
Currently the config_write_stats_reporter function does not output
the mtu value, which is fixed by this commit.
Sponsored-by: On-Waves ehf
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
If the MTU is given, combine several messages into a single UDP
packet until the limit is reached. Flush all reporters after the
values have been scanned.
New vty commands (node config-stats):
mtu <100-65535> Enable multi-metric packets and set the maximum
packet size (in byte)
no mtu Disable multi-metric packets
Note that single messages that are longer than the given MTU (minus
28 octets protocol overhead) will be dropped.
Sponsored-by: On-Waves ehf
|
|
|
|
|
|
|
|
| |
This calls stats_flush in regular intervals which polls the
statistical values and calls the active reporters when values have
changed.
Sponsored-by: On-Waves ehf
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
This commit provides stats configuration similar to the log
configuration.
The following vty commands are added to the config node:
stats reporter statsd Create/Modify a statsd reporter
no stats reporter statsd Remove a statsd reporter
To actually configure a reporter, the config-stats node is entered
when the "stats reporter" command has succeeded. The following new
vty commands are available there:
local-ip ADDR Set the IP address to which we bind locally
no local-ip Do not bind to a certain IP address
remote-ip ADDR Set the remote IP address to which we connect
remote-port <1-65535> Set the remote port to which we connect
prefix PREFIX Set the item/counter name prefix
no prefix Do not use a prefix
enable Enable the reporter
disable Disable the reporter
Sponsored-by: On-Waves ehf
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
This file will contain the VTY code related to statistics.
This commit adds a minimal file with just as single VTY command:
- show stats This command shows all statistical values
To enable this and future commands, the main program needs to call
stats_vty_add_cmds().
Sponsored-by: On-Waves ehf
|
|
|
|
|
|
|
| |
This functions shows the state of all osmo_counters, stat_item
groups, and counter groups.
Sponsored-by: On-Waves ehf
|
|
|
|
|
|
|
|
|
|
| |
Currently the groups for stat_items and counter are iterated
manually.
This commit makes use of the new iterator functions to access the
single elements via handlers.
Sponsored-by: On-Waves ehf
|
|
|
|
|
|
| |
This functions dumps a whole stat item group to the VTY.
Sponsored-by: On-Waves ehf
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
We are mixing enums and hope that no short-enums are used. This
is leading to a lot compiler warnings generated by clang. Change
the API to work with integers.
Porting:
The go_parent_cb implementations in the applications need to be
fixed. The API change leads to a compile time warning.
Fixes:
abis_om2000_vty.c:46:2: warning: implicit conversion from enumeration type 'enum bsc_vty_node' to
different enumeration type 'enum node_type' [-Wenum-conversion]
OM2K_NODE,
^~~~~~~~~
|
|
|
|
|
| |
Fix copy and paste issue introduced by Holger in
2d6ad13d8daf860595e6d4025861e122ce574871.
|
|
|
|
|
| |
This got introduced in 2d6ad13d8daf860595e6d4025861e122ce574871
and I thought that our vty tests would have caught such mistakes.
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |
We want to see from which category/subsystem a certain log message
is coming from and use a different timestamp format as well. Add
two new bitfields. This doesn't change the size of the structure
and on 32bit we still have 27bits left.
The extended timestamp will take preference over the current and
default timestamp format.
Fixes: SYS#602
|
|
|
|
|
|
|
|
|
| |
For the BSC/NITB application we see that people modify the band
without modifying the ARFCN. This creates an unbootable config.
Using the new hook the BSC/NITB can check if the config is
consistent and prevent the config file being written.
Related: SYS#739
|
| |
|
|
|
|
| |
.. Nuttx doesn't know u_long
|
|
|
|
| |
... u_char not being defined on Nuttx.
|
|
|
|
|
| |
Preprocessor flags are best placed in AM_CPPFLAGS. Remove use of the
unused all_includes variable, which is never set.
|
|
|
|
|
|
| |
the bits/crc files are not inside the sourcedirectory but will end
in the build directory. Go and look there as well. This somehow
doesn't fail with make distcheck but when building for Yocto Dizzy.
|
|
|
|
|
|
| |
This enables the persistent configuration of let's say
'log filter imsi 012345678' for a given log file in the config
file.
|
| |
|
|
|
|
|
| |
EBADFD is linux specific while EBADF is POSIX. Fix the build on
FreeBSD and use EBADF throughout the file.
|
|
|
|
|
|
| |
If the read callback closes the connection conn is already freed so we
can't derefernce it. Instead return -EBADFD in the read function if it
closed the connection and check for that.
|
|
|
|
|
|
|
|
|
| |
The testcase didn't work on Ubuntu 12.04 because vty_create will
directly call vty_event (e.g. not through the plt). This means
that the approach to override vty_event in the testcase failed.
Use the signal interface of libosmocore and make the testcase
use it. The signals can be generally useful as well.
|
|
|
|
|
|
|
| |
This patch removes an assertion of node > CONFIG_NODE and changes
the function to handle all nodes properly.
For the sake of completeness, the generic 'exit' command
implementation is extended to work properly with all nodes, too.
|
|
|
|
|
| |
In this case the last_node variable may hold values that are not
in enum node_type, so int is used instead.
|
|
|
|
|
|
|
|
|
|
|
| |
This adds the vty_install_default() function that is basically the
install_default() function plus the registration of the commands
'exit' and 'end'. The latter is only provided in subnodes of
ENABLED_NODE and CONFIG_NONE.
The VTY test program is extended to check these commands.
Ticket: OW#952
|
|
|
|
|
|
| |
Put all 'exit' logic into vty_go_parent() and replace the
implementations of 'exit' and 'end' by generic ones that use
vty_go_parent().
|
|
|
|
|
| |
The function is_config() returns 0 for CONFIG_NODE. Since that node
is a config node, the function is renamed to resolve this.
|
|
|
|
|
| |
In vty_cmd_string_from_valstr() include the real string lengths of
the sep and end arguments into the buffer size calculation.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Compiled with ubuntu 1204 (precise), where -Wformat-security is enabled by
-Wall.
Test yields ok, but the current implementation doesn't properly support
multi-character separators and end strings. So the test output is truncated.
Addresses:
utils.c: In function 'vty_cmd_string_from_valstr':
utils.c:84:2: warning: format not a string literal and no format arguments [-Wformat-security]
utils.c:84:2: warning: format not a string literal and no format arguments [-Wformat-security]
utils.c:108:2: warning: format not a string literal and no format arguments [-Wformat-security]
utils.c:108:2: warning: format not a string literal and no format arguments [-Wformat-security]
|
|
|
|
|
|
|
|
|
|
| |
The code most likely wanted to check the result of argv_concat.
To do this we need to dereference the dptr.
Logically dead code (DEADCODE)
dead_error_line: Execution cannot reach this statement "return 1;
Fixes: Coverity CID 1040675
|
|
|
|
|
|
|
|
|
|
| |
These routines were not freeing vectors used for the lookup. On
review it is fixing another path not detected by coverity.
The danger is a double free in tab completion now. It is difficult
to test this.
Fixes: Coverity CID 23037, CID 23038
|
| |
|
|
|
|
|
| |
When we print information about the current logging configuration,
it makes sense to also print information about the log filters.
|
|
|
|
|
|
| |
Only the Gb library relies on having undefined references to a
symbol that needs to be provided by the host application. For
all other libraries we can link with -no-undefined.
|
|
|
|
|
|
|
| |
The log target can be used via log alarms and show alarms.
Why? This feature was proposed/requested at
http://openbsc.osmocom.org/trac/wiki/Tasks/ErrorLogTarget
All messages use the same amount of space, prioritizing simplicity.
|