| Commit message (Collapse) | Author | Age | Files | Lines |
|
|
|
| |
Change-Id: I7df6858bb98abffc1d5bf420f991ae5854b24638
|
|
|
|
| |
Change-Id: Ifb3115c7488fbcf082cc9b92abc25cf7c46064e0
|
|
|
|
|
|
|
|
|
|
|
| |
incomplete to vty func
For instance, take command "single0 [one]":
If user executes "single0 on", VTY func will receive argv[0]="one"
instead of argv[0]="on".
Related: OS#4045
Change-Id: I5f4e2d16c62a2d22717989c6acc77450957168cb
|
|
|
|
|
|
|
|
|
|
|
| |
vty func
For instance, take command "multi0 (one|two|three)":
If user executes "multi0 tw", VTY func will receive argv[0]="two"
instead of argv[0]="tw".
Fixes: OS#4045
Change-Id: I91b6621ac3d87fda5412a9b415e7bfb4736c8a9a
|
|
|
|
|
|
| |
This block will become bigger in forthcoming commits.
Change-Id: Ibc1494014b1e77ce10950f7268a44d2d2091a6f2
|
|
|
|
|
|
|
| |
Check against MAX argc is changed to == since it cannot be incremented
twice without passing the check.
Change-Id: Ia330e475989fda863bedcc3cbf94deaf8dd83037
|
|
|
|
|
|
|
|
| |
Huge conditional block inside for loop is negated in this patch
together with a "continue" keyword, similar to what was already done
recently in 4742526645d6137dd90ef369f0415afdb91736dc.
Change-Id: I803c4ed38e9ab09bf929528c75a60e6f65da3928
|
|
|
|
|
|
|
| |
Makes code easier to follow because enum values no longer look like
variables.
Change-Id: Ib6e9592c5962d047869a280c10f9b557fae6f435
|
|
|
|
|
|
|
|
|
|
| |
inner block defined variable "enum match_type ret" was being masking
outter block variable "int ret = 0". The ret variable was being given
non zero values only inside the inner block, so that change was done on
the inner variable and not the outer one, which is returned.
Fixes: 5314c513f23688462d7f7937e5ae5e0d5cd4548e
Change-Id: Iec87d7db49a096d07e38ff8a060b923a52bfd6ba
|
|
|
|
|
|
|
| |
Huge conditional block inside foor loop is negated in this patch
together with a "continue" keyword.
Change-Id: I9715734ed276f002fdc8c3b9742531ad36b2ef9e
|
|
|
|
|
|
| |
Otherwise it's a bit hard to read the code.
Change-Id: I807ec71cfb67976251be844cdb2d2776b1837438
|
|
|
|
|
|
|
|
|
|
|
|
| |
libosmo{core,gsm,vty} code is GPLv2+. The tdef code originated in
osmo-msc.git and was moved here without changing the license. That
was a mistake, it always was meant to be under GPLv2-or-later after
moving to libosmocore.git.
Copyright is with sysmocom, so I as the managing director can
approve the license change.
Change-Id: Ie483ff6f6ea0a56c477649677b4b163c49df11d7
|
|
|
|
| |
Change-Id: I351411ca5913c8b40f23287ec7c9ebfe11bd2bb0
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
For async callbacks it is useful to determine whether a given VTY pointer is still valid.
For example, in osmo-msc, a silent call can be triggered by VTY, which causes a
Paging. The paging_cb then writes to the VTY console that the silent call has
succeeded. Unless the telnet vty session has already ended, in which case
osmo-msc crashes; e.g. from an osmo_interact_vty.py command invocation. With
this function, osmo-msc can ask whether the vty pointer passed to the paging
callback is still active, and skip vty_out() if not.
Change-Id: I42cf2af47283dd42c101faae0fac293c3a68d599
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Move from a static implementation in tdef_vty.c to utils.c, I also want to use
this in osmo-msc.
The point is that the telnet VTY allows unambiguous partly matches of keyword
args. For example, if I have a command definition of:
compare (apples|oranges)
then it is perfectly legal as for the vty parser to write only
compare app
One could expect the VTY to then pass the unambiguous match of "apples" to the
parsing function, but that is not the case.
Hence a VTY function implementation is faced with parsing a keyword of "app"
instead of the expected "apples".
This is actually a very widespread bug in our VTY implementations, which assume
that exactly one full keyword will always be found. I am now writing new
commands in a way that are able to manage only the starts of keywords.
Arguably, strstr(a, b) == a does the same thing, but it searches the entire
string unnecessarily.
Change-Id: Ib2ffb0e9a870dd52e081c7e66d8818057d159513
|
|
|
|
|
|
|
| |
We don't need to know position of matches: just yes or no.
This change would save some computation power.
Change-Id: Id55ffe64cc1a35dd83f61dbb0f9828aa676696f9
|
|
|
|
|
|
| |
There is no need to allocate struct 'walk_cb_params' dynamically.
Change-Id: I96f25f1ddb36b19b12055deaeeb6f58e59180e72
|
|
|
|
|
|
|
|
|
|
|
|
| |
The naming of these constants dates back to when the code was private
within OpenBSC. Everything else was renamed (bsc_fd -> osmo_fd) at
the time, but somehow the BSC_FD_* defines have been missed at the
time.
Keep compatibility #defines around, but allow us to migrate the
applications to a less confusing naming meanwhile.
Change-Id: Ifae33ed61a7cf0ae54ad487399e7dd2489986436
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
The amount of arguments is already being checked a few lines before:
/* If any arguments are missing, redirect to 'show' */
if (argc < 3)
return show_timer(self, vty, argc, argv);
so we cannot reach the expression NULL inside this statement:
group_arg = argc > 0 ? argv[0] : NULL;
Change-Id: Ice59d1a46c2080cd02060e3410706c502db4ce0b
Fixes: CID#190873 Logically dead code (DEADCODE)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
fi->T values are int, i.e. can be negative. Do not log them as unsigned, but
define a distinct timer class "Xnnnn" for negative T values: i.e. for T == -1,
print "Timeout of X1" instead of "Timeout of T4294967295".
The negative T timer number space is useful to distinguish freely invented
timers from proper 3GPP defined T numbers. So far I was using numbers like
T993210 or T9999 for invented T, but X1, X2 etc. is a better solution. This way
we can make sure to not accidentally define an invented timer number that
actually collides with a proper 3GPP specified timer number that the author was
not aware of at the time of writing.
Add OSMO_T_FMT and OSMO_T_FMT_ARGS() macros as standardized timer number print
format. Use that in fsm.c, tdef_vty.c, and adjust vty tests accordingly.
Mention the two timer classes in various API docs and VTY online-docs.
Change-Id: I3a59457623da9309fbbda235fe18fadd1636bff6
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Move T_def from osmo-bsc to libosmocore as osmo_tdef. Adjust naming to be more
consistent. Upgrade to first class API:
- add timer grouping
- add generic vty support
- add mising API doc
- add C test
- add VTY transcript tests, also as examples for using the API
From osmo_fsm_inst_state_chg() API doc, cross reference to osmo_tdef API.
The root reason for moving to libosmocore is that I want to use the
mgw_endpoint_fsm in osmo-msc for inter-MSC handover, and hence want to move the
FSM to libosmo-mgcp-client. This FSM uses the T_def from osmo-bsc. Though the
mgw_endpoint_fsm's use of T_def is minimal, I intend to use the osmo_tdef API
in osmo-msc (and probably elsewhere) as well. libosmocore is the most sensible
place for this.
osmo_tdef provides:
- a list of Tnnnn (GSM) timers with description, unit and default value.
- vty UI to allow users to configure non-default timeouts.
- API to tie T timers to osmo_fsm states and set them on state transitions.
- a few standard units (minute, second, millisecond) as well as a custom unit
(which relies on the timer's human readable description to indicate the
meaning of the value).
- conversion for standard units: for example, some GSM timers are defined in
minutes, while our FSM definitions need timeouts in seconds. Conversion is
for convenience only and can be easily avoided via the custom unit.
By keeping separate osmo_tdef arrays, several groups of timers can be kept
separately. The VTY tests in tests/tdef/ showcase different schemes:
- tests/vty/tdef_vty_test_config_root.c:
Keep several timer definitions in separately named groups: showcase the
osmo_tdef_vty_groups*() API. Each timer group exists exactly once.
- tests/vty/tdef_vty_test_config_subnode.c:
Keep a single list of timers without separate grouping.
Put this list on a specific subnode below the CONFIG_NODE.
There could be several separate subnodes with timers like this, i.e.
continuing from this example, sets timers could be separated by placing
timers in specific config subnodes instead of using the global group name.
- tests/vty/tdef_vty_test_dynamic.c:
Dynamically allocate timer definitions per each new created object.
Thus there can be an arbitrary number of independent timer definitions, one
per allocated object.
T_def was introduced during the recent osmo-bsc refactoring for inter-BSC
handover, and has proven useful:
- without osmo_tdef, each invocation of osmo_fsm_inst_state_chg() needs to be
programmed with the right timeout value, for all code paths that invoke this
state change. It is a likely source of errors to get one of them wrong. By
defining a T timer exactly for an FSM state, the caller can merely invoke the
state change and trust on the original state definition to apply the correct
timeout.
- it is helpful to have a standardized config file UI to provide user
configurable timeouts, instead of inventing new VTY commands for each
separate application of T timer numbers.
Change-Id: Ibd6b1ed7f1bd6e1f2e0fde53352055a4468f23e5
|
|
|
|
|
|
|
|
|
| |
Provide a va_list type vty_out() variant, to be able to pass on variable
arguments from other function signatures to vty_out().
This will be used by Ibd6b1ed7f1bd6e1f2e0fde53352055a4468f23e5 for osmo_tdef.
Change-Id: Ie6e6f11a6b794f3cb686350c1ed678e4d5bbbb75
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Remove any special node exiting from the VTY CTRL-C handling.
From a curious VTY transcript test glitch, I noticed weird behavior by the VTY
telnet shell: usually, when the user hits CTRL-C, that means to cancel the
current command line and present a fresh, clean prompt. However, only on the
CONFIG_NODE and CFG_LOG_NODE, a CTRL-C also exits the current node and moves up
by one level. This behavior is unexplainable and makes zero sense.
No other nodes exit on CTRL-C:
- on the ENABLE node, a CTRL-C stays on the ENABLE_NODE and doesn't exit to the
VIEW_NODE.
- any sub-nodes of the CONFIG_NODE stay unchanged, e.g. 'network' or 'bts' /
'trx', etc.
There is no apparent special meaning of CTRL-C on CONFIG_NODE nor CFG_LOG_NODE
to justify this odd choice.
Particularly, the vty transcript tests using osmo_verify_transcript_vty.py rely
on sending CTRL-C to clear the command prompt, so that we can properly test
sending '?' to the VTY during transcripts. In a live session, a '?' prints
available options and then updates the prompt with identical command arguments.
In a transcript test, that doesn't make sense, because each time the transcript
writes out a new command to run. Consider e.g. a transcript test like:
tdef_vty_test(config)# timer ?
tea Tea time
test Test timers
software Typical software development cycle
tdef_vty_test(config)# timer tea ?
[TNNNN] T-number, optionally preceded by 't' or 'T'.
To be able to issue a fresh command after '?', osmo_verify_transcript_vty.py
explicitly sends a CTRL-C to clear the command buffer. Hence there we rely on
predictable behavior of CTRL-C.
More particularly, the upcoming osmo_tdef_vty transcript tests are apparently
the first that want to test '?' behavior on the CONFIG_NODE's root level and
fall on their face, because of the implicit exit that happens only there.
Change-Id: I4f339ba61f1c273fa7da85caf77ba116ae2697b1
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
In cmd_complete_command_real(), detect and strip square braces from
multi-choice arguments, to enable tab-completion for commands like
> list
cmd [(alpha|beta)]
> cmd <TAB>
alpha beta
> cmd be<TAB>
> cmd beta
Change-Id: I8c304300b3633bb6e9b3457fcfa42121c8272ac0
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Since very recently we sensibly handle commands like
cmd ([one]|[two]|[three])
as optional multi-choice arguments. In addition, support the more obvious
syntax of
cmd [(one|two|three)]
Internally, the tokens are mangled to [one] [two] and [three], which is how the
rest of the code detects optional args, and makes sense in terms of UI:
> cmd ?
[one]
[two]
[three]
(i.e. optional arguments are always shown in braces in '?' listings)
Before this patch, commands defined with a syntax like [(one|two)], would lead
to an assertion (shows as "multiple") during program startup.
Change-Id: I952b3c00f97e2447f2308b0ec6f5f1714692b5b2
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Add basic optional multi-choice argument support.
The VTY detects optional arguments by square braces.
> cmd ?
[optional-arg]
> cmd optional-arg
ok
> cmd
ok
However, within multi-choice args, these braces were so far not treated as
optional:
> list
cmd2 ([one]|[two]|[three])
> cmd2
% Command incomplete
In preparation for I952b3c00f97e2447f2308b0ec6f5f1714692b5b2 which will enable
the more obvious syntax of
cmd [(one|two)]
for reasons of internal implementation, first support a syntax of
cmd ([one]|[two])
The internal vty implementation always needs square braces around each option.
There is currently no good way to prevent developers from defining braces
inside multi-arguments, so it is easiest to allow and handle them:
> list
cmd2 ([one]|[two]|[three])
> cmd2
ok
The VTY doesn't guard against a mix like
cmd (one|[two])
With this patch, a multi-choice command is treated as optional iff the first
element is in square brackets. The remaining elements' square brackets have no
effect besides confusing the user. This is not explicitly checked against.
In general, I would prefer to check all of these details, but the current VTY
code with its endless code duplication and obscure string mangling just doesn't
provide that luxury. There are numerous worse errors hidden in there.
Change-Id: I9a8474bd89ddc2155c58bfca7bd038d586aaa60a
|
|
|
|
| |
Change-Id: I1bd973754b1ebc42283f6a07defa60f58523f5a3
|
|
|
|
|
|
|
|
|
| |
In 99ae401e490e60fc07bef7eacc478be7bdcc9f5a we introduced the ability
to specify the TCP port to which the VTY should bind. However, the VTY
dcumentation wasn't extended accordingly, causing virtually all master
build jobs to fail.
Change-Id: I54fb0ca0d3a884a64a349b22de70f3d9bd1a6d54
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Extend the vty_bind_cmd VTY command to allow to optionally specify
a port in addition to the IPv4 address.
Introduce telnet_init_default to relieve client code from having
to query the bind IPv4 address (and now the TCP port). Instead a
client only needs to pass the default TCP port to use.
Client code should use it like:
int rc = telnet_init_default(ctx, priv, OSMO_VTY_PORT_SGSN);
Change-Id: Id5fb2faaf4311bd7284ee870526a6f87b7e260f3
|
|
|
|
| |
Change-Id: I38555c4d4f565ce21dda34fc3857c47b3d802dbd
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Show each rate counter group's index in the output of the
'show rate-counters' command, to provide some way of telling
apart distinct instances of the same rate counter group.
This is not a very user-friendly UI because these indices are
generated internally by libosmocore and/or applications, so
users cannot easily assign meaning to these indices. However,
the current rate counter implementation doesn't allow for more.
Change-Id: Ieb151239407e4b2f8859fefec8d0670f5ddf908a
Related: OS#3674
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
When vty_out_rate_ctr_group_fmt() prints the description of a
counter group, it assumes this description should appear at
the beginning of a line. However, the caller might be printing
counters in an indented context. So just let the caller worry
about printing the group title if necessary (there is currently
only one known caller, which is updated in this commit).
Note that printing of the group title was an undocumented feature.
Change-Id: I2c55cb54e8b7a7c8c6cf72f22287083767ed0201
Related: OS#2660
|
|
|
|
|
|
|
| |
Adjust wording so telnet command can be directly copy-pasted from the log to access
the interface without the need for further editing.
Change-Id: I1876447f9285adcd1b09937a6121afabd0b32e52
|
|
|
|
| |
Change-Id: I07d105f4a810dd809fbf6feb5c04e7410020c887
|
|
|
|
|
| |
Change-Id: Ibd81f29fa22d53553bd73c055d6a1f5255a69bad
Fixes: Coverity CID#135238
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
We must explicitly check the return value of osmo_log_vty2tgt(), or may run
into a segfault. I wasn't aware of this and introduced numerous such cases in
I36f17c131cc70ce5a1aef62fd9693097de230cd4.
Reproduce: on the VTY, do not issue 'logging enable', invoke 'logging level
force-all LEVEL' first.
Show in logging_vty_test.vty that this situation is now again amended by
telling the user that logging was not enabled.
Related: OS#3611
Change-Id: Id11702d1801d6654ca5e5a51b597a0d802e2e8dd
|
|
|
|
|
|
|
| |
We want to have well-formed config files that print exactly one space
per VTY/config node level, and not two.
Change-Id: Ia75c7067284ea225cffe13ca71bad05a7747ae66
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
During 'show online help', the XML vty node dump, omit all commands marked
HIDDEN.
These commands were already hidden from the VTY reference prior to commit
I1f18e0e41da4772d092d71261b9e489dc1598923, because of broken/confusing bit and
boolean logic mixup. After that commit, HIDDEN commands end up in the doc. So
practically, this patch here brings back the status quo of before above commit,
even though the previous code clearly "intended" to list HIDDEN commands in the
reference but failed to have that effect.
AFAICT the complete list of commands currently hidden is:
* osmo-bsc: bts/"training_sequence_code <0-7>",
* osmo-bsc: ts/"phys_chan_config PCHAN" for uppercase pchans;
* osmo-bts: bts/"rtp bind-ip A.B.C.D" which actually says
vty_out(vty, "%% rtp bind-ip is now deprecated%s", VTY_NEWLINE);
* osmo-sgsn: 'reset sgsn state' used for SGSN testing.
Note that the osmo-sgsn build was broken by including hidden commands in the
vty reference, since one of its hidden commands had missing doc strings and
made osmotestconfig.py signal failure. This would fix that from the
hide-hidden-commands angle, and so would osmo-sgsn commit
I8b6e8615e409266910f2f76a10ced9ab33e4de91 from the fix-the-doc-strings angle.
Change-Id: I92c3c66ff69c186234276c64478d6342e061d25e
|
|
|
|
|
|
|
|
|
|
| |
If a command is both hidden and deprecated, still don't show it for the 'list'
command.
We currently have no such nodes, as it seems, though.
Related: OS#3584
Change-Id: I07ec15cab057a3e09064e0420a69121ee8eb4253
|
|
|
|
|
|
|
|
|
|
|
| |
In vty_dump_nodes(), make sure the bitwise & is evaluated first.
For the deprecation flag (0x1), the practical effect is most likely identical,
assuming that the boolean ! operator flips the first bit, so I expect no
visible functional difference. It still was confusing and wrong to look at.
Related: OS#3584
Change-Id: I1f18e0e41da4772d092d71261b9e489dc1598923
|
|
|
|
|
|
|
|
|
| |
Add new command to once-off set each and every category to the given log level,
as discussed at length on the openbsc@ mailing list.
Show that it works in logging_vty_test.vty.
Change-Id: I4c3e4f786476cb813fdc0a7c64f30ee04758309d
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Add 'logging level force-all <level>' and 'no logging level force-all' as new
names for 'logging level all <level>' and 'logging level all everything'.
Resurrect the functionality of 'logging level all everything' -- even if it is
still deprecated because the name is confusing, it is now just an alias for
'no logging level force-all'.
Show in logging_vty_test.vty that we can now again lift the global logging
clamp, both with the new commands as well as with the deprecated ones.
Also show that 'force-all' is written back properly, if set.
Change-Id: I36f17c131cc70ce5a1aef62fd9693097de230cd4
|
|
|
|
| |
Change-Id: If683b1272ad2d5b402b91c52c496aa7975bc6315
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
The 'logging level all everything' has not had an effect for some time now. The
plan is to bring back its old functionality, but to keep it deprecated and
rather define a less confusing name.
* Deprecate 'everything'.
* Do not write 'everything' during 'write file' or 'show running-config', which
we curiously still do until now.
BTW, the reason why we need to compose a complete list of categories for the
deprecated 'everything' command is explained in detail in the commit log for
I3b083f27e3d751ccec258880ae7676e9af959a63
Change-Id: Ib75fedb0572570a61bb34ee729a2af86cf5f16da
|
|
| |