| Commit message (Collapse) | Author | Age | Files | Lines |
|
|
|
| |
Allow to tag the NS service with a custom DSCP.
|
|
|
|
|
|
|
|
|
| |
This is changing the semantic of the assert. The regression tests
now either need to check the stderr result, the exit status or print
a message when all tests are completed.
This is not that bad as the osmo_generate_backtrace is printing to
the stdout right now.
|
|
|
|
|
| |
This function will re-open all existing log files in the application,
praticularly useful for SIGHUP handlers in case of logrotate
|
| |
|
| |
|
| |
|
|
|
|
|
| |
The tests should unconditionally assert, regardless of debug settings.
This uses the OSMO_ prefix as it's in the global namespace.
|
|
|
|
|
|
|
| |
The log target can be used via log alarms and show alarms.
Why? This feature was proposed/requested at
http://openbsc.osmocom.org/trac/wiki/Tasks/ErrorLogTarget
All messages use the same amount of space, prioritizing simplicity.
|
|
|
|
|
|
|
| |
I noticed some more issues and it is the easiest to revert and include
the fixed version.
This reverts commit 73377229bb33ab79682ce4b126a63602d13304ad.
|
|
|
|
|
|
|
| |
The log target can be used via log alarms and show alarms.
Why? This feature was proposed/requested at
http://openbsc.osmocom.org/trac/wiki/Tasks/ErrorLogTarget
All messages use the same amount of space, prioritizing simplicity.
|
| |
|
|
|
|
|
| |
Doxygen generates quite a lot of warnings on libosmocore. Some of them
are obvious typos - this patch aims to fix such low-hanging fruit.
|
|
|
|
| |
without this, we break e.g. the openbsc build...
|
|
|
|
|
|
| |
this will avoid printing 'abis_nm.c' as the filename in the log, which
is pretty useless during debugging. We want to know where
abis_nm_debugp_foh() is being used from, not where it is implemented.
|
|
|
|
|
| |
This is required for CPUs < armv6, to access 16 and 32 values at right
memory locations.
|
|
|
|
| |
Signed-off-by: Sylvain Munaut <tnt@246tNt.com>
|
| |
|
|
|
|
|
|
| |
Extracted from a patch by Max Suraev Max.Suraev@fairwaves.ru>
Signed-off-by: Sylvain Munaut <tnt@246tNt.com>
|
|
|
|
|
|
|
|
|
|
| |
When OpenBSC is handling more than one message at a time it is difficult
to see which log message belongs to which SMR instance. Introduce a
uint64_t id that can be set to the row_id/message_id and prefix all
log messages with SMR(ID).
This change is ABI and API incompatible with previous versions of
libosmogsm.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
When OpenBSC is handling more than one message at a time it is difficult
to see which log message belongs to which SMC. Introduce a uint64_t id
that can be set to the row_id/message_id and prefix all log messages
with SMC(ID).
This change is ABI and API incompatible with previous versions of
libosmogsm.
Example:
SMC(100) instance created
SMC(100) message MNSMS-EST-REQ received in state IDLE
|
|
|
|
|
|
|
|
| |
msgb_pull returns a pointer to the new begin of the
buffer, unlike msgb_get(), where those functions
were originally taken from.
Signed-off-by: Steve Markgraf <steve@steve-m.de>
|
|
|
|
| |
The code embeds the timer so one needs to include the header file.
|
|
|
|
|
| |
Without the "extern" keyword the variables in this header file will be
seen as empty definitions when compiled on OSX.
|
|
|
|
|
| |
When you are in the config-log VTY node, you expect "end" to work
like in any other sub-node of config.
|
| |
|
| |
|
|
|
|
|
|
| |
Introduce a print_filename attribute for each logtarget. Initialize it
with 1 to be backward compatible with earlier versions. The bit is taken
from an existint bitfield. There were at least six bits left of the byte.
|
|
|
|
|
|
| |
Applications should keep the log area in a static const area. Mark
the pointer as const to address compiler warnings in OpenBSC, cast
the const away for the osmo_log_info as it is not declared as const.
|
| |
|
|
|
|
| |
.. not sure how we could have missed that so far.
|
|
|
|
|
|
| |
msgb_get() has been wrong all the time, despite the documentation being
correct. If you've used the broken msgb_get() before, you have to
change your code now, sorry.
|
|
|
|
|
| |
this ensures that we can talloc the flow-control queue entries
as siblings off the bvc_ctx.
|
|
|
|
|
|
|
| |
* add more comments on units of struct members
* make sure to parsre FC-BVC message correctly
* add error message in case user passes PDU larger than bucket size
* add new function to initialize flow control struct
|
|
|
|
|
|
|
|
| |
This code is supposed to implement the BSSGP flow control algorithm,
both for the per-BSS and for the per-MS flow control.
The code currently has no test cases, they will come in a separate
commit.
|
| |
|
| |
|
| |
|
|
|
|
| |
Also adds a test case for both encoder and decoder of this IE
|
| |
|
|
|
|
|
| |
This function is able to generate a VTY help string based on an
array of 'struct value_string'.
|
|
|
|
|
|
|
| |
Add parentheses around the OSMO_MAX and OSMO_MIN macro to match
the behaviour of calling a function. The current version does not
evaluate to what is expected. (OSMO_MAX(3, 2) + 13) currently
results in 3 and not 16.
|
|
|
|
|
|
| |
The OpenSUSE build is not happy about the uint8_t to uint8_t*
assignment. As the suspend_ref is a mandatory field we can make
it a plain uint8_t. Increase the LIBVERSION as the ABI has changed.
|
| |
|
|
|
|
|
|
| |
I recently discovered that we can only print backtraces to stdout, which
is of course useless in a daemon environment. We'd rather want to use
the libosmocore logging framework instead.
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
This new TLV type is specific to TS 44.318. Contrary to the TvLV type
of TS 08.16/08.18, it has an inverted meaning of the extension (0x80)
bit:
* if the extension bit is not set, 1-byte length
* if the extension bit is set, 2-byte length
Futhermore, it has support for variable-length tags, where the tag part
can be optionally two bytes in length. As this esoteric option hasn't
been seen in the wild yet, we only add encoding support but skip
decoding for now.
|
| |
|
| |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Make sure the declaration and definition match, add const to
the functions called by logp/logp2.
Compile output:
logging.c:317: error: conflicting types for 'logp'
../include/osmocom/core/logging.h:34: note: previous declaration of 'logp' was here
logging.c:327: error: conflicting types for 'logp2'
../include/osmocom/core/logging.h:168: note: previous declaration of 'logp2' was here
make[3]: *** [logging.lo] Error 1
|
|
|
|
|
|
| |
this patch i use to suppress warnings when compiling osmo-pcu (c++).
since __FILE__ is constant, the called logging function with parameter
"file" must be constant too, in order to avoid compiler warnings.
|